Performance improvement of 5-kW household air-to-water heat pump
รหัสดีโอไอ
Creator P. TRINURUK, S. CHUMNANWAT, S. PREMPREESUK, S. PASANTA and S. SANITJAI
Title Performance improvement of 5-kW household air-to-water heat pump
Publisher Thai Society of Mechanical Engineers
Publication Year 2559
Journal Title Journal of Research and Applications in Mechanical Engineering
Journal Vol. 4
Journal No. 1
Page no. 116-125
Keyword Coefficient of Performance (COP), Air-to-Water Heat pump, Vapor compression cycle, Thermostatic expansion valve, Condensing coil
ISSN 2229-2152
Abstract Heat pump can take the advantage in higher performance than other technologies such as electric heater for producing hot water in household. In theoretical, the heat pump can transfer heat 3-4 times larger than the electric energy consumed which can identify the performance of heat pump in term of Coefficient of Performance (COP). However, the development of 5-kW household air-to-water heat pump with simple system design from previous work can achieve the COP only 2.37 following the standard testing of EN255-3 when the test condition was adapted for Thailand's weather at the ambient temperature of 25 ?C and 70% relative humidity. Nevertheless, it still has some margin for improving the COP. Therefore, the objective of this study was to improve the performance of household air-to-water heat pump to meet the target of 10% COP increase. In this study, two improvement methods were proposed based on vapor compression system analysis and the realistic with the low investment approaches. Two methods of performance improvement were the increase of degree of subcooling at the condenser outlet by increasing the heating surface area of condensing coil, and the increase of evaporator pressure accompanied with decreasing in the degree of superheat at the evaporator outlet by changing expansion device from capillary tube to thermostatic expansion valve. The step improvement of heat pump performance, i.e. existing system, increasing the heating surface of condensing coil, using thermostatic expansion valve, and the combination of increasing the heating surface of condensing coil and changing thermostatic expansion valve, were confirmed by testing in the control room under the standard with the same condition. The results shown that the combination of both modifications can efficiently improve the COP of heat pump up to 2.64 or 11.38% higher than the existing system. In the viewpoint of the investment cost, the improvement of the full modification invested about 368 THB per 1% COP increase which was more attractive than the other such as changing the type of compressor.
Journal of Research and Applications in Mechanical Engineering

บรรณานุกรม

EndNote

APA

Chicago

MLA

ดิจิตอลไฟล์

Digital File
DOI Smart-Search
สวัสดีค่ะ ยินดีให้บริการสอบถาม และสืบค้นข้อมูลตัวระบุวัตถุดิจิทัล (ดีโอไอ) สำนักการวิจัยแห่งชาติ (วช.) ค่ะ