Synthesis of carbon nanotube-tungsten oxide composite for carbon dioxide sensing application
รหัสดีโอไอ
Title Synthesis of carbon nanotube-tungsten oxide composite for carbon dioxide sensing application
Creator Siriporn Monchayapisut
Contributor Tawatchai Charinpanitkul, Mana Sriyudthsak
Publisher Chulalongkorn University
Publication Year 2554
Keyword Composite materials, Nanotubes, Carbon, Tungsten oxides, Gas detectors, Carbon dioxide, วัสดุเชิงประกอบ, ท่อนาโน, คาร์บอน, ทังสะเตนออกไซด์, อุปกรณ์ตรวจจับก๊าซ, คาร์บอนไดออกไซด์
Abstract For employing as sensing materials, multi-walled carbon nanotubes-tungsten oxide (MWCNT-WO₃) composites were synthesized by using acid precipitation method following by calcination under air atmospheres. The research procedure was divided into 3 steps including investigation of WO₃ synthesis, synthesis of MWCNT-WO₃ composites, and investigation of gas sensing ability of as-prepared sensing materials. In the step of synthesis of tungsten oxide nanoparticles, it was found that the suitable condition with the highest percent yield of 71.4% was obtained from precipitation of 5.3 mM tungsten salt and 10 M nitric acid at 80°C for 30 min and then calcine at 400°C for 1 hour. In the second step, MWCNT-WO3 composites were then synthesized with different mass ratio of MWCNTs to tungsten salt according to the suitable precipitation and calcination condition. The actual mass ratio (MWCNTs: WO₃) is in a range of 0.4:100 to 8.5:100. In the last step, three sensing materials including WO₃ nanoparticles, MWCNT-WO₃ composites, pristine MWCNTs were employed to prepare in-house fabricated thick film gas sensors by facile drop coating method. Sensing ability of all fabricated sensor were tested by exposure to CO₂ with concentration of 500 ppm at room temperature to 200°C. Gas sensors prepared from WO₃ calcined at 400°C would exhibit higher sensitivity to CO₂ than that calcined at 300 °C or 600°C. For the composites as sensing materials, the fabricated sensor with the smallest ratio of MWCNTs to WO₃ (0.4:100) could provide three times sensitivity higher than the sensors prepared from WO₃ nanoparticles. With the optimum ratio of MWCNTs to WO₃ (1.5:100), the sensors could also respond to CO₂ at the lowest operating temperature of 50°C with high sensitivity of 41.0% and the shortest response time of 19.1 seconds. It means that the operating temperature could be reduced four times from 200°C to 50°C when the composites at this ratio (1.5:100) were used instead of WO₃ nanoparticles.
URL Website cuir.car.chula.ac.th
Chulalongkorn University

บรรณานุกรม

EndNote

APA

Chicago

MLA

ดิจิตอลไฟล์

Digital File #1
DOI Smart-Search
สวัสดีค่ะ ยินดีให้บริการสอบถาม และสืบค้นข้อมูลตัวระบุวัตถุดิจิทัล (ดีโอไอ) สำนักการวิจัยแห่งชาติ (วช.) ค่ะ