A COMPARISON STUDY OF THREE DIFFERENT HEART RATE MONITORING DEVICES
รหัสดีโอไอ
Creator Kittichai THARAWADEEPIMUK
Title A COMPARISON STUDY OF THREE DIFFERENT HEART RATE MONITORING DEVICES
Contributor Ampika NANBANCHA, Weerawat LIMROONGREUNGRAT
Publisher The Sports Science Society of Thailand (SSST)
Publication Year 2565
Journal Title Journal of Sports Science and Technology
Journal Vol. 22
Journal No. 2
Page no. 104-120
Keyword Heart Rate, Chest Strap Heart Rate Sensor (Polar), Low-Cost Smart Watch (Watch), Heart Rate Plus Mobile Application (App)
URL Website https://he01.tci-thaijo.org/index.php/JSST/index
Website title Journal of Sports Science and Technology
ISSN 1513-7201;2672-927X
Abstract Heart rate (HR) monitoring during resting and exercises has been widely used as an indicator of cardiorespiratory or aerobic fitness. Presently, there has been a large increase in the number of wearable devices that use to measure HR such as smart watch and mobile application. With technological advancement, the cost of these devices is reduced. However, some models are still not precise for estimating HR. Therefore, the purpose of this study was to compare and assess validity of three HR monitoring devices; chest strap heart rate sensor (Polar), low-cost smart watch (Watch), and Heart Rate Plus mobile application (App). HR measurement was recorded in 1 minute (average, maximum, and minimum) following recording ranges: (1) resting state, (2) after 15 repetitions of Jumping Jack, (3) after 2 minutes rest, (4) after 15 repetitions of Jumping Jack, (5) after 2 minutes rest. The HR values from 3 instruments were statistically different in every recording range by using Friedman. When evaluated validity of the HR values compared to Polar across all recording ranges, the standardize typical error of estimates were 3.74-79.60 and 0.16-2.09 for Watch and App, respectively. In addition, Bland Altman plot was described a comparison of HR values between Polar and Watch and Polar and App. The difference between Polar and Watch distributed outside the area of the mean difference line (abnormally distributed). The difference between Polar and App distributed in the area of the mean difference line (normally distributed). The percentage difference between Watch and App heart rate values compared to Polar heart rate values is shown in terms of the percentage change. Consequently, this study can provide information to choose the HR measurement. Watch might not be valid for monitoring exercise. App is valid for monitoring resting state, but not portable and easy to use in exercise
สมาคมวิทยาศาสตร์การกีฬาแห่งประเทศไทย

บรรณานุกรม

EndNote

APA

Chicago

MLA

ดิจิตอลไฟล์

Digital File
DOI Smart-Search
สวัสดีค่ะ ยินดีให้บริการสอบถาม และสืบค้นข้อมูลตัวระบุวัตถุดิจิทัล (ดีโอไอ) สำนักการวิจัยแห่งชาติ (วช.) ค่ะ