Assessment of CareStartTM G6PD RDT for G6PD deficiency screening in newborns and malaria diagnosed subjects in the Northern Thailand
รหัสดีโอไอ
Creator 1. Nattasit Pienthai
2. Chedtapak Ruengdit
3. Suphara Manowong
4. Kanyakan Kongthai
5. Kritsanee Maneewong
6. Kankanitta Pongmorn
7. Maneewan Inta
8. Nardlada Hhantikul
9. Aungkana Saejeng
10. Sakorn PornprasertNattasit Pienthai
11. Chedtapak Ruengdit
12. Suphara Manowong
13. Kanyakan Kongthai
14. Kritsanee Maneewong
15. Kankanitta Pongmorn
16. Maneewan Inta
17. Nardlada Hhantikul
18. Aungkana Saejeng
19. Sakorn Pornprasert
Title Assessment of CareStartTM G6PD RDT for G6PD deficiency screening in newborns and malaria diagnosed subjects in the Northern Thailand
Publisher Faculty of Associated Medical Sciences, Chiang Mai University
Publication Year 2562
Journal Title Journal of Associated Medical Sciences
Journal Vol. 52
Journal No. 1
Page no. 78-82
Keyword Accuracy, CareStartTM G6PD RDT, Fluorescent spot test, G6PD deficiency, ScreeningAccuracy, CareStartTM G6PD RDT, Fluorescent spot test, G6PD deficiency, Screening
URL Website https://www.tci-thaijo.org/index.php/bulletinAMS/index
Website title Journal of Associated Medical Sciences
ISSN 25396056
Abstract Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an inherited enzymatic disorder associated with severe neonatal hyperbilirubinemia and acute hemolysis after exposure to certain drugs or infections. The most common test for screening G6PD deficiency is fluorescent spot test which is rapid and convenient. However, fluorescent spot test needs tools and skills in diagnosis and interpretation of the results. CareStartTM G6PD Rapid Diagnosis Test (RDT) is an enzyme chromatographic strip test based on reduction of colorless nitro blue tetrazolium into formazan which gives purple color and the results could be read within 10 minutes. Objective: This study aimed to analyze the sensitivity, specificity and accuracy of CareStartTM G6PD RDT for screening of G6PD deficiency in newborn and subjects with malaria diagnosis. Materials and methods: This study was conducted from December 2017 to February 2018. G6PD diagnostic tests including fluorescent spot test and CarestartTM G6PD RDT were performed in 196 newborns aged varied from 1 day to 12 years and 48 subjects with malaria diagnosis. The efficiency of CareStartTM G6PD RDT was analyzed by comparing with the reference method, fluorescent spot test. Results: CareStartTM G6PD RDT demonstrated 100% sensitivity, 100% specificity and 100% accuracy for screening of G6PD deficiency in malarial diagnosed samples. However, it presented invalid results up to 27.04% in newborns. Therefore, sensitivity, specificity and accuracy were not applicable in this group. Conclusion: CareStartTM G6PD RDT could be used for preliminary screening of G6PD deficiency in malarial diagnosed samples. However, it should be improved to reduce the invalid results in newborns.
Journal of Associated Medical Sciences

บรรณานุกรม

EndNote

APA

Chicago

MLA

ดิจิตอลไฟล์

Digital File
DOI Smart-Search
สวัสดีค่ะ ยินดีให้บริการสอบถาม และสืบค้นข้อมูลตัวระบุวัตถุดิจิทัล (ดีโอไอ) สำนักการวิจัยแห่งชาติ (วช.) ค่ะ