Method Validation of a Solid Phase Extraction, High Performance Liquid Chromatography and Electrochemical Detection Method for Determination of Azithromycin in Human Plasma
รหัสดีโอไอ
Creator Sukanya Supattanapong
Title Method Validation of a Solid Phase Extraction, High Performance Liquid Chromatography and Electrochemical Detection Method for Determination of Azithromycin in Human Plasma
Contributor Julraht Konsil, Bung-orn Sripanidkulchai, Jeffery Roy Johns
Publisher Faculty of Pharmaceutical Sciences KKU MSU UBU
Publication Year 2551
Journal Title Isan Journal ofPharmaceutical Sciences
Journal Vol. 4
Journal No. 1
Page no. 25-33
Keyword Azithromycin, solid-phase extraction, validation, HPLC, Oasis HLB
URL Website https://tci-thaijo.org/index.php/IJPS
Website title Isan Journal ofPharmaceutical Sciences, IJPS
ISSN 19050852
Abstract An effective and sensitive method for the determination of azithromycin in plasma with high performance liquid chromatography (HPLC) and electrochemical detection extracted by solid phase extraction has been developed and validated. Clarithromycin was used as an internal standard. Azithromycin was extracted from 1 ml of plasma by using an Oasisยฎ HLB (Hydrophilic-Lipophilic Balance) solid-phase extraction cartridge. After eluting with 1 ml of methanol, the sample solution was evaporated to dryness, dissolved in 100 ฮผl phosphate buffer-methanol-acetonitrile (60:20:20, v/v/v) and 40 ฮผl injected into the HPLC system. The lower limit of quantitation (LLOQ) was 10 ng/ml without interfering peaks. The calibration curve was linear (rยฒ = 0.9998) over the concentration range from 10 to 400 ng/ml. The accuracy and precision were in acceptable range according to criteria of guideline for Industry: Bioanalytical Method Validation of the US FDA (2001). The mean recoveries at 30, 100 and 200 ng/ml were 85.3ยฑ5.5%, 80.1ยฑ6.8% and 82.9ยฑ2.5%, respectively. Azithromycin was stable in plasma for at least 6 h at room temperature and 6 months stored at -80ยฐC. The post-preparative stability of spiked-samples was stable more than 24 h after preparation. The cartridge can be used two times providing deviation less than 4%. The method can be used for determination of azithromycin in plasma in pharmacokinetic study, bioavailability and bioequivalence.
Faculty of Pharmaceutical Sciences, Khon Kaen University

บรรณานุกรม

EndNote

APA

Chicago

MLA

ดิจิตอลไฟล์

Digital File
DOI Smart-Search
สวัสดีค่ะ ยินดีให้บริการสอบถาม และสืบค้นข้อมูลตัวระบุวัตถุดิจิทัล (ดีโอไอ) สำนักการวิจัยแห่งชาติ (วช.) ค่ะ